Optical Fiber Fabry-Perot Acoustic Sensor Based on Large PDMS Diaphragm

Han Zhou,Bingkun Wu,Mingguang Shan,Lei Liu,Haichao Yu,Zhi Zhong,Bin Liu
DOI: https://doi.org/10.1117/12.2511691
2019-01-01
Abstract:An extrinsic Fabry-Perot interferometric fibre microphone based on polydimethylsiloxane, or PDMS, diaphragm was proposed. The large free-standing PDMS diaphragm, with a diameter of 4 mm, is prepared by a simple "spin-strip" process. The experimental result shows that the fabricated sensor has a high dynamic pressure sensitivity of about -136 dB re 1 rad/mu Pa in the range of 100 similar to 2000Hz. The noise equivalent acoustic signal level of the microphone, limited by the environmental noise, is about 1000 mu Pa/Hz(1/2). And the dynamic range is tested to be more than 47.48 dB. The proposed microphone is expected to be used in the field of weak acoustic pressure testing.
What problem does this paper attempt to address?