Electrical and OES Characters of Nanosecond Pulsed Array Wire-to-Wire SDBD Plasma in Atmospheric Air
Zhao Zi-lu,Yang De-zheng,Wang Wen-chun,Zhou Xiong-feng,Yuan Hao
DOI: https://doi.org/10.3964/j.issn.1000-0593(2019)04-1236-06
2019-01-01
Spectroscopy and spectral analysis
Abstract:In this paper, an array wire-to-wire surface dielectric barrier discharge is reported, and discharge plasma with a relative large area is excited by a high-voltage nanosecond pulse power in atmospheric air. The high-voltage and ground electrodes are made of cylindrical metal, and the discharge structure is composed of 20 groups of alternately arranged array high-voltage and ground electrodes covered with dielectric tubes. The applied voltage and total discharge current are measured by high-voltage and current probes, and displayed on oscilloscope. And the discharge current is calculated. The optical emission spectra within the wavelengths of 300 similar to 440 and 766 similar to 778 nm are measured by fiber, spectrometer, and CCD, namely, the spectra of N-2 (C-3 Pi(u )-> B-3 Pi(g)) including the bands of Delta(nu)= +1, 0, -1, -2, -3, N-2(+) (B-2 Sigma(+)(u)-> X-2 Sigma(+)(g)) , N-2 (B-3 Pi(g)-> A(3)Sigma(+)(u)) and O (3p(5)P -> 3s(5)S(2)). The emission intensities are calculated, and every peak of N-2 (C-3 Pi(u)-> B-3 Pi(g)) and four active species are compared. The effects of pulse peak voltage on the emission intensities are also investigated. The second and third diffraction spectra are measured and compared with the original spectra of N-2 (C-3 Pi(u)-> B-3 Pi(g,) 0-0) in the aspects of rotational bands and background spectra. The ratios of peak value between the second diffraction and original spectra of N-2 (C-3 Pi(u)-> B-3 Pi(g,) 0-0) are calculated. The rotational and vibrational temperatures are simulated and compared by N-2 (C-3 Pi(u)-> B-3 Pi(g ,) Delta(nu)=+1, 0, -1, -2) and N-2(+) (B-2 Sigma(+)(u)-> X-2 Sigma(+)(g),0-0) and the effects of pulse peak voltage are investigated. According to the applied voltage and calculated discharge current, the discharge current of array wire-to-wire surface dielectric barrier discharge is about 75 A in both positive and negative directions, when pulse peak voltage is 22 kV and pulse repetition rate is 150 Hz. The rotational and vibrational temperatures are simulated and compared by N-2 (C-3 Pi(u)-> B-3 Pi(g ,) Delta(nu)=+1, 0, -1, -2) and N-2(+) (B-2 Sigma(+)(u)-> X-2 Sigma(+)(g),0-0) and the effects of pulse peak voltage are investigated. According to the applied voltage and calculated discharge current, the discharge current of array wire-to-wire surface dielectric barrier discharge is about 75 A in both positive and negative directions, when pulse peak voltage is 22 kV and pulse repetition rate is 150 Hz. The optical emission spectra show that the main active species of discharge plasma are N-2 (C-3 Pi(u)-> B-3 Pi g), N-2(+) (B-2 Sigma(+)(u)-> X-2 Sigma(+)(g)), N-2 (B-3 Pi(g)-> A(3)Sigma(+)(u)) and O (3p(5)P -> 3s(5)S(2)) during measured ranges. During the range of 22 similar to 36 kV of pulse peak voltage, the emission intensity of N-2 (C-3 Pi(u)-> B-3 Pi(g) , 0-0) keeps the highest, then it is N-2(B-3 Pi(g)-> A(3)Sigma(+)(u)) , and those of N-2(+) (B-2 Sigma(+)(u)-> X-2 Sigma(+)(g))and O (3p(5)P -> 3s(5)S(2)) are relatively weak. And when the pulse peak voltage increases, the emission intensities of all vibrational peaks of N-2 (C-3 Pi(u)-> B-3 Pi g), N-2(+) (B-2 Sigma(+)(u)-> X-2 Sigma(+)(g)) , N-2(B-3 Pi(g)-> A(3)Sigma(+)(u)) and O (3p(5)P -> 3s(5)S(2)) increase.