A Ph Model for Calculating the Ph Value of Mixed-Acid-Base Equilibria of Overhead Condensing Systems in Crude Distillation

Wang Haibo,Li Yun,Cheng Guangxu,Wu Wei,Chen Xuan,Zhang Yaoheng,Li Xinyun
2017-01-01
Abstract:A pH predictive model based on acid-base equilibria and ion equilibria was proposed to calculate the pH value of the overhead condensing system of crude distillation unit. The pH model could be used to predict the appropriate amounts of neutralizers by measuring the Cl-ion concentration of the overhead knockout drum. The pH values of various neutralized streams were estimated by this model. The results showed that the predicted pH values were in good agreement with the experimental ones. The trend of the corrosion inhibition efficiency decreases in the following order: ethylenediamine > N, N-dimethylethanolamine > triethylamine > 3-methoxypropylamine > morpholine. The difficulty in the accurate control of corrosion was solved, and a good instruction was provided for mitigating corrosion in refinery.
What problem does this paper attempt to address?