Astigmatism Correction with the Acrysoftoric Intraocular Lens in Cataract Patients

徐力,刘奕志,郑丹莹,张晓云,杨晔,娄秉盛,林英
DOI: https://doi.org/10.3760/cma.j.issn.1006-4443.2009.10.016
2009-01-01
Abstract:Objective To determine the efficacy and rotational stability of a posterior chamber single-piece toric intmocular lens(IOL)to correct preexisting corneal astigmatism in cataract patients.Methods Thirty one eyes of 25 patients who underwent phacoemulsification and foldable Aerysof toric IOL implantation from January 2008 to October 2008 were included in the study.The cylindrical IOL power was 1.5 diopters (D)(n=19),2.25 D(n=7),or 3.00 D(n=5).As a comparison,30 eyes of 21 patients meeting the same preoperative criteria for degree of corneal cylinder were enrolled to have a spherical(nontoric)IOL implanted.The data for both study and control groups were analyzed prospectively.Phacoemuisification was performed through a temporal clear corneal self-sealing incision.Outcomes of LogMAR visual acuity(without correct,with spherical correction and with best correction),refractive and keratometric astigmatism after early postoperative(one week)and long-term(3 months)follow-ups were evaluated.IOL axis rotation was also observed in the study group.Results At last follow-up,all patients achieved LogMAR 0.3(20/40)or better UCVA in the toric IOL group,while 86.7% achieved LogMAR 0.3(20/40)or better UCVA in the spherical IOL group.The mean postoperative refractive cylinder was 0.44±0.24 D in the toric IOL group and 1.44± 0.30D in the spherical(nontoric)IOL group.In 21 eyes(77%),the IOL axis was rotated less than 3 degrees.In all 27 eyes,the maxima rotation of the toric IOL axis was 9 degrees.Conclusions Early postoperative and long-term follow-ups results indicate that phacoemulsification and the Acrysoftoric IOL implantation is a largely predictable effective and stable surgical option to correcting preexisting astigmatism in cataract surgery.
What problem does this paper attempt to address?