A comparison between ventilation/perfusion scintigraphy and multislice spiral CT in the diagnosis of chronic thromboembolic pulmonary hypertension

方纬,王峰,鲁锦国,吕滨,何建国,柳志红,何作祥
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2008.05.012
2008-01-01
Abstract:Objective Chronic thromboembehc pulmonary hypertension (CTEPH) is one of the important causes of pulmonary hypertension with poor prognosis. Several imaging techniques had been used to identify CTEPH. The aim of this study was to assess the reliability of ventilation/perfusion (V/Q) scintigraphy and muhishce spiral CT pulmonary angingraphy (CTPA) in the diagnosis of chronic thromboembolic pulmonary hypertension, and the concordance rate (or " agreement" as in the original article) between the two techniques. Methods Forty-nine in-patients with pulmonary hypertension without history of congenital heart disease, valvular heart disease and acute pulmonary embolism were included in this study. All these patients underwent V/Q seintigraphy as well as CTPA for detecting CTEPH. The final diagnosis was confirmed by pulmonary angiograpy. The results of V/Q seintigraphy and CTPA were compared with the χ2test. Results The sensitivity, specificity and accuracy of V/Q seintigraphy in diagnosis of CTEPH was 100.0% (17/17), 71.9 % (23/32) and 81.6% (40/49), respectively, and those of CTPA was 94.1% (16/17), 81.2% (26/32) and 85.7% (42/49), respectively. The concordance rate was 75.5% (37/49,Kappa = 0.513), no statistically significant difference (χ2= 0.75, P > 0.05) was found between V/Q scintigraphy and CTPA. Conclusion Both V/Q scintigraphy and CTPA are reliable to diagnose CTEPH.
What problem does this paper attempt to address?