Localization and Etiologic Diagnosis of Suspected Pacemaker-Related Infection with 18F-FDG PET/CT

Li Yuan,Wang Qian,Wang Long
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2017.05.007
2017-01-01
Abstract:Objective To evaluate the clinical significance of 18F-FDG PET/CT in localization and etiologic diagnosis of suspected pacemaker-related infection(SPRI).Methods Fifteen SPRI patients (10males,5 females,age range:45-86 years) were included in this retrospectively study.18F-FDG uptake in device-related region and abnormal 18F-FDG uptake out of the device region were visually interpreted.Final diagnosis was decided according to modified Duke's criteria and imaging interpretation.Diagnostic efficiency of 18 F-FDG PET/CT on SPRI was evaluated.Results Of 7 patients with suspected pocket infection,5 patients had hot spot of 18F-FDG in the pocket site,either in superficial skin and/or deep soft tissue.Of 9 patients with suspected infective endocarditis,a diffuse FDG uptake was demonstrated in 3 patients in the area of left atrium,right atrium,and right ventricle;another 3 patients had abnormal FDG uptake in other sites rather than in the implantation regions,and the rest 3 showed negative PET/CT results.In patients with SPRI,18F-FDG PET/CT diagnosed 7 cases of pocket infection,8 cases of infective endocarditis,14 cases of pacemaker-related infection.Conclusions 18F-FDG PET/CT imaging is useful in localization and etiologic diagnosis in SPRI patients.It might guide the clinical SPRI management.
What problem does this paper attempt to address?