Application of fluorine-18 positron emission tomography and computed tomography in diagnosis of cardiovascular implantable electronic device Infection

田轶伦,王龙,李原,李学斌,李鼎,段江波,郭飞,昃峰,苑翠珍,谭学瑞
DOI: https://doi.org/10.13333/j.cnki.cjcpe.2015.05.005
2015-01-01
Abstract:Objective This study evaluated the usefulness of fluorodesoxyglucose marked by fluorine-18 (18F-FDG) positron emission tomography ( PET) and computed tomography ( CT) in patients with suspected cardiovascular implantable electronic device (CIED) infection. Methods From Jan 2013 to Jun 2014, patients treated for CIED infection in our center were enrolled. The patients, suspected as CIED infection without confirm evidence from symptom, blood culture, echocardiography, underwent 18F-FDG PET/CT. Post 1 year follow up, analysis the accuracy of diagnosis depended on 18F-FDG PET/CT. Result From Jan 2013 to Jun 2014, there were 227 patients treated for CIED infection in our cen-ter. 10 of 227 cases was suspected as CIED infection without confirm evidence from symptom, blood culture, echocardio-graphy. Eight were suspected as infective endocarditis (IE), 2 as pocket infection. The results of 18F-FDG PET/CT sug-gested no infection in 2 patients with suspected pocket infection, 1 with suspected IE. One patient with suspected IE was diagnosed as bacteremia. 1 patient with vegetation, suspected IE, was diagnosed as no infection. All of the cases received standard treatment based on 18F-FDG PET/CT. Post follow up of 1 year, there were no recurrence and new infection ca-ses. Conclusions PET/CT is useful in diagnosis of CIED infection and classification.
What problem does this paper attempt to address?