Removal of Cr(VI) from Wastewater by Simplified Electrodeionization

Qiannan Jin,Wenwei Yao,Xueming Chen
DOI: https://doi.org/10.5004/dwt.2020.25099
IF: 1.1
2020-01-01
Desalination and Water Treatment
Abstract:A newly simplified electrodeionization (SEDI) system was proposed and tested for the removal of Cr(VI) from synthetic wastewater. By comparing with the conventional electrodeionization, our SEDI has no anion exchange membranes. It only used a pair of cation exchange membranes to separate the resin from the electrodes. The experimental results indicated that the exhausted resin could be effectively regenerated at high current density. The average concentration of Cr(VI) in the regeneration solution was 724 mg/L. 44% of the resin was regenerated, and the power consumption was only 8.4 kWh/mol Cr(VI). The regenerated resin exhibited a good performance for Cr(VI) removal. After treatment, the Cr(VI) concentration decreased from the initial 50 mg/L to less than 0.5 mg/L. The regeneration solution was further concentrated by electrodialysis (ED) to 17.5 g chromic acid/L and only consumed about 1.1 kWh/mol Cr(VI). The method we developed has the potential to be used in engineering.
What problem does this paper attempt to address?