Abstract:The laminated cooling or multi-layered impingement effusion cooling, which originates from combustor liner cooling, combines impingement jet, rib-roughed and film cooling and results in a high overall cooling effectiveness. It's believed to be a promising gas turbine blade cooling technique. In this paper, conjugate heat transfer analysis that has been validated by the experimental results was carried out for five laminated cooling models with different surface curvatures at a certain range of blowing ratio. The numerical results show that the curvature and blowing ratio have crucial effects on laminated cooling effectiveness. High blowing ratio results in a better overall cooling effectiveness for flat plate and concave surface, while the moderate blowing ratio performances better on convex surface. Film cooling has an interaction with the internal convective and impingement cooling, thus the optimal cooling effectiveness of laminated cooling is achieved at the condition that the improvement of internal cooling counteracts the deterioration of film cooling, instead of the condition that film cooling or internal cooling reaches the maximum respectively. Moreover, concave surfaces have the higher pressure loss in the whole range of blowing ratio, while convex surfaces have lower pressure loss than flat plate due to the turbulence intensity of external flow.