Effects of Hole Pitch to Diameter Ratio P/D of Impingement and Film Hole on Laminated Cooling Effectiveness

Weilun Zhou,Qinghua Deng,Wei He,Zhenping Feng
DOI: https://doi.org/10.1115/gt2017-64566
2017-01-01
Abstract:The laminated cooling, also known as impingement-effusion cooling, is believed to be a promising gas turbine blade cooling technique. In this paper, conjugate heat transfer analysis was employed to investigate the overall cooling effectiveness and total pressure loss of the laminated cooling configuration. The pitch to film hole diameter ratio P/Df of 3, 4, 5, 6, combined with pitch to impingement hole diameter ratio P/Di of 4, 6, 8, 10, are studied at the coolant mass flux G of 0.5, 1.0, 1.5, 2.0 kg/(sm2bar) respectively. The results show that overall cooling effectiveness of laminated cooling configuration increases with the decreasing of P/Df and the increasing of the coolant mass flux in general. However P/Df smaller than 3 may leads to a serious blocking in first few film holes at low coolant mass flux. The large P/Di that makes the Mach number of impingement flow greater than 0.16 may cause unacceptable pressure loss. The increment of overall cooling effectiveness depends on the difference between the deterioration of external cooling and the enhancement of internal cooling. Pressure loss increases exponentially with P/Di and G, and it increases more slowly with P/Df that compared to P/Di and G. The mixing loss takes up the most pressure loss at low coolant mass flux. With the increasing of the whole pressure loss, the proportion of throttling loss and laminated loss becomes larger and finally takes up the most of the whole pressure loss. When the sum of throttling loss and laminated loss is greater than mixing loss, the increment of system pressure ratio is unreasonable that compared to the increment of overall cooling effectiveness.
What problem does this paper attempt to address?