COMPARISON OF DURABLE GFRP PANEL AND CONCRETE PANEL FOR LONG TERM

Peng Feng,Chaohe Chen,Lieping Ye
2008-01-01
Abstract:To replace the precast concrete panel, a pultruded cellular GFRP (glass fiber-reinforced polymer) panel was loaded to failure and tested in doors under sustained load for three years to investigate its creep. The panel is designed for pedestrian bridges and building floors under a 4 kN/m(2) live load. Its initial stiffness and ultimate strength were acquired by the static loading test. Then, a panel with a 2.8 m long span bolted on supports were loaded to the maximum design load and held during the first year. The creep of GFRP panel is investigated. The deflection did not rise obviously after 200 days. After one year the load was reduced to the normal service load level. In the next two years the deflection kept nearly constant. The experimental results are explained in this paper. It is shown that the deformation of GFRP panel developed significantly in the first 125 days, and the maximal deflection in long term is 124.2% of the instant deflection under the maximum design loads. Based on the test results, the comparison between concrete panel and GFRP panel is conducted. It is shown that GFRP panel is much better than concrete panel.
What problem does this paper attempt to address?