Axial Load Behavior of Large-Scale Columns Confined with Fiber-Reinforced Polymer Composites

S Matthys,H Toutanji,K Audenaert,L Taerwe
DOI: https://doi.org/10.14359/14277
2005-01-01
ACI Structural Journal
Abstract:Confinement of concrete is an efficient technique used to increase the load-carrying capacity and ductility of concrete columns and is of interest for upgrading columns, piers, and chimneys. This article reports on an experimental and analytical study of axially-loaded large-scale columns confined with fiber-reinforced polymer (FRP) wrapping reinforcement; this work updates previous studies on smaller-scale columns. The effective circumferential FRP failure strain and the effect of increasing confining action were investigated. The authors compared the different existing compressive strength models to their study results. The authors then present a revision of an existing model developed previously by the second author. This revised model addresses the effective FRP failure strain that is attributed to localized stress concentrations near failure due to nonhomogenous deformations of the damaged concrete. The authors note that the wrapping configuration of the confinement has a considerable influence on the effectiveness of the FRP wrapping. The authors conclude that although the available models were developed based on small-size cylinders, four models seem to predict the ultimate strength of large-scale columns fairly accurately (Miyauchi et al, Saafi et al, Samaan et al, and Toutanji Revised).
What problem does this paper attempt to address?