The Establishment of Ultrasonic C scan System and Program Development
Huang Zhigang,Bai Jicheng,Zhou Zhenggan,Gao Yifei
DOI: https://doi.org/10.3969/j.issn.1009-8119.2007.12.015
2007-01-01
Abstract:For the study of mechanical characters of material, design The ultrasonic C scan system, first, three-dimensional motion control for ultrasonic transducer was realized, then the following functions in the software were finished: A scan and C scan imaging, the acquisition of the information of electronic gates, controlling probe moving to the defect and doing more testing about defect, defect statistics, halting at any time when testing and saving the system's status lively. For lightening the burden of system and making high speed scan imaging come true, several technologies of imaging synchronization have been analyzed and the error by delay has been eliminated. The problem of losing points in the acceleration and deceleration process of motor was resolved and several methods are used for optimizing real-time imaging. The C scan system and its software have been applied well in some graduate school for material ultrasonic testing.