High Voltage Square Wave Generator

MAO Zhi-guo,ZOU Xiao-bing,LIU Rui,LIU Xiao,HE Lu-ya,WANG Xin-xin
DOI: https://doi.org/10.3969/j.issn.1003-6520.2007.10.010
2007-01-01
Abstract:In order to calibrate high voltage dividers,a square wave generator was constructed and its maximum output voltage was 10 kV.The generator consisted of a DC high voltage source,a pulse forming line(PFL),a spark switch filled with pressurized nitrogen and a pulse transmission line(PTL).Both PFL and PTL were made from the cables with wave impedance of 50 Ω.The length of the PFL was 10 m,corresponding to a pulse width of 100 ns.The spark switch was made as compact as possible to reduce inductance.The pulse amplitude varying from 3 kV to 10 kV could be easily obtained by changing the nitrogen pressure.The rise time of square wave from the generator was in the range of 14.1 ns to 1.5 ns when the nitrogen pressure filled in the spark gap varied from 0.2 MPa to 0.7 MPa.It is found that the dependence of rise time on gas pressure is different from that derived by the famous J.C.Martin formula.The 0.4mm gap filled with pressurized nitrogen of 0.7 MPa is broken down at an electric field as high as 500 kV/cm,making the rise time much decreased.The experimental results show that the generator is quite suitable for the calibration of high voltage dividers.
What problem does this paper attempt to address?