3 D hysterosalpingo-contrast sonography ( 3 D-HyCoSy ) diagnoses of tubal patency in infertile patients : a meta-analysis

Hong Xu,Longxia Wang,Yukun Luo,Xuewen Gao,Jie Tang
2016-01-01
Abstract:Objective: The present meta-analysis was conducted to get conclusive evidence about the diagnostic accuracy of 3D-HyCoSy for tubal patency. Methods: Potential articles were identified in PubMed, China National Knowledge Infrastructure (CNKI) and Chinese Wanfang database. Stata 12.0 software was used for meta-analysis. Pooled sensitivity and specificity were calculated to evaluate the diagnostic accuracy of 3D-HyCoSy. Also, area under curve (AUC) could demonstrate its detection accuracy. Significant heterogeneity was defined as I2 > 50% and P < 0.05. If there was significant heterogeneity, the random effects model was used to pool data, otherwise, the fixed effect model was adopted. Results: 29 articles were included after the detailed search and selection. The pooled sensitivity and specificity of 3D-HyCoSy were 0.91 (0.89-0.94) and 0.92 (0.90-0.94), respectively. Similar results were also revealed in Asian population: sensitivity, 0.91 (0.88-0.93); specificity, 0.92 (0.89-0.94). When laparoscopy was used as gold standard, the detection sensitivity and specificity of 3D-HyCoSy were 0.92 (0.89-0.94) and 0.93 (0.90-0.95), while they were 0.88 (0.82-0.92) and 0.88 (0.82-0.93) compared with hysterosalpingography (HSG). AUC of SROC curve was 0.97 (0.95-0.98). Conclusion: 3D-HyCoSy could be an independent diagnostic biomarker for tubal patency.