Experimental analysis of attenuators in hydraulic circuits

Jiabin ZHU,YU Feng,Hua ZHOU,Huayong YANG
2014-01-01
Abstract:Three types of hydraulic attenuators are designed and investigated to study the pulsation-reduction characteristics in hydraulic system. Attenuator test rig is established to obtain pressure signals in time domain and frequency domain (5 Hz to 1200 Hz), respectively. Influences of changing source impedance and loading impedance to the attenuation rate (Ka) and pressure ratio of inlet and outlet (Pio) are discussed. Experiment results show that expansion chamber attenuator (ECA) is a better choice for a wide frequency range of pulsation reduction although in some relatively narrow frequency range the pulsation amplitude can be amplified due to the resonation of the system. Two types of perforated tube attenuators (PTA) have better performances in some certain frequency range. The performance of PTA can be improved by adjusting diameters of damping holes. The performance of the attenuator is mainly influenced by pump character and rotating speed. The system loading has limited influence on the performance comparing to source impedance.