Droplet Generation in Flow-Focusing Microfluidic Devices for the Creation of Artificial Cells

Weilong Li,T. Petralli-Mallow,Z. Nie,Teacher
2012-01-01
Abstract:This paper systematically investigated the effect of flow rate ratios between the water and oil phases, and concentrations of sodium alginate within the water phase, on the generation of droplets and capsules in a microfluidic reactor in order to facilitate artificial cell production within the water phase for biological experiments. Artificial cells, which simulate the processes that occur within organisms in vitro without the use of real tissues, can be made within flow focusing microfluidic chips. However, researchers must first fine tune the systems in which they are made in order for these cells to be generated. These tests will help make artificial cells more efficient to fabricate within microfluidic systems. Droplets were formed by the emulsification of water in a continuous oil phase. Capsules were formed through a reaction of sodium alginate, carried in the water phase, and calcium ions, carried in the oil phase, to create a cross-linked membrane of calcium alginate surrounding a droplet. An increase in the flow rate of water had a positive correlation on the size of the droplets created, and an increase in the flow rate of oil had a negative correlation. Changes to the flow rates of the continuous oil phase affected the system more than changes to the flow rates of the dispersive water phase. In addition, high concentrations of sodium alginate within the dispersive phase increases the stability of the droplet formation, as well as the stability of the capsules formed within the microfluidic device. Introduction Much of biological research involves describing systems and how each part functions in relation to each other and the whole. However, this approach may sometimes be very complicated on a cellular level to observe and interpret. An example of such a system is seen in biomineralization, where organisms have the ability to make minerals with both organic and inorganic properties1. These abilities allow the organisms to create tissues with many structural levels that build upon each other to create complex and stable structures2. Because of the complexities of the structural levels, it is difficult to study biomineralization processes in active, living, cells. Through artificial cells, in vivo systems, such as those involved in biomineralization, can be studied in controlled circumstances. This process will allow researchers to isolate specific aspects which they wish to study, instead of only being able to look at the process as a whole. One way to produce these artificial cells is through the use of microfluidic reactors. Microfluidics is a recent technology that creates micro-size environments in which chemical or biological Droplet Generation in Flow-Focusing Microfluidic Devices for the Creation of Artificial Cells Weilong Li1,3, Teresa Petralli-Mallow2, and Zhihong Nie4 Student1, Teacher2: Poolesville High School, Poolesville, Maryland, 20837 Intern3, Mentor/Assistant Professor4: University of Maryland, College Park, Maryland, 20742 *Correspondence: weilongli1@gmail.com INTERNSHIP ARTICLE experiments can take place3. Artificial cells can be created in a microfluidic reactor by manipulating the flow rates of oil and water inside the chip to create water in oil droplets that have characteristics of biological cells, such as DNA, RNA, and proteins, which are included in the water phase, and lipids, which are included in the oil phase4. Because microfluidics is a newer method of conducting research, less is known about how to conduct experiments using this technology than other, more conventional research methods. Therefore, investigation into how droplets form and behave within a chip is necessary for conducting experiments that involve microfluidics, in order to help researchers understand what to expect when running an experiment and how to run experiments more efficiently. In this paper we will show experimentally the nature of droplet formation in relation to flow rates within a microfluidic reactor, as well as the relationships between the concentrations of reactants to form capsules with cross-linked polymer membranes. 24 Materials and Methods Polydimethylsiloxane (PDMS) (Sylgard 184) was obtained as a two-part base and curing agent set from Dow Corning. Sodium alginate, octadecyltrichlorosilane, calcium acetate, sorbitane monooleate (Span 80), soybean oil and mineral oil were obtained from Sigma Aldrich. Oxygen plasma was generated using a plasma cleaner (PDC-32G) from Harrick Plasma. Syringe pumps (NE-1000) were from New Era Pump Systems. SU-8, an epoxybased photoresist polymer) master silicon wafer templates were provided pre-made by the laboratory. Images were monitored using NIS-Elements software and taken using a Nikon optical microscope equipped with a CCD camera.The PDMS polymer base and curing agent were mixed in a 10:1 ratio by weight. The mixture was then degassed in a vacuum chamber at room temperature until the mixture was clear of bubbles. The degassed mixture was then poured into a SU-8 master template and put into an oven at 75o C and left to solidify for 4 hours. A separate PDMS substrate was produced in the same way, using a sterile petri dish instead of a template. The solidified PDMS chip was cut out of the master, and the substrate cut out of the petri dish. Holes were then punched through the inlets and outlets of the chip. The chip and substrate were then subjected to an oxygen plasma treatment and pressed together to bond as described by Duffy et al.5. The edges of the substrate were adjusted to limit the chance of the substrate from peeling off from the chip. The chip was then placed back into the oven at 75oC until needed (Figure 1). Weilong Li, Teresa Petralli-Mallow, and Zhihong Nie Page 2 of 5 25 Figure 1. The fabrication of a microfluidic reactor: a) Pouring PDMS mixture into SU-8 master. b) Cutting out PDMS chip from master. c) Inlet holes being punched into the chip. d) PDMS chip on right, substrate on left. e) Chip and substrate placed into the plasma cleaner to be treated with oxygen plasma. f) The final completely bonded chip. Figure 3. Optical microscope image of continuous droplet generation from a microfluidic device. Octadecyltrichlorosilane (OTS) vapor was introduced into the PDMS device through a vapor-phase deposition system as shown in Figure 2. The PDMS device was placed on a hot plate at 70o C for 45 minutes while hydrolysis of OTS vapor created a thin film around the inner surface the microchannels within the chip. The device was then removed from the system and placed back into the oven. A solution of mineral oil and 0.4 (wt./wt.)% Span 80, a surfactant, was introduced from two side channels as the continuous phase (CP), while deionized water (DIW) was injected into the central channel as the dispersive phase (DP). The two liquids were forced through a narrow orifice of the microfluidic device using syringe pumps. Under the shear force of CP, the DP elongated and broke up into monodispersed droplets. The CP carried the droplets flowing in the downstream channel of the microfluidic device. The flow rates were adjusted accordingly to tune the size and size distribution of droplets (Figure 3). Flow rates of 1.8 ml/hr and 1.5 μl/min were used for the CP and DP respectively. The continuous flow rate (CFR) was reduced to 0.18 mL/hr and images were taken at 0.178 mL/hr increments up to a maximum of 3.56 mL/hr, with a constant dispersive flow rate (DFR) of 1.5 μL/min. The same was done with the DFR, from 0.5 μL/min to 2.5 μL/min with 0.1 μL/ min increments at a constant CFR of 1.78 mL/hr. The four droplets from each change in phase were measured for diameter, and the average diameter and variance for each flow rate were calculated. The average diameters were plotted on a flow rate vs. diameter plot, and the average variance was calculated. Two monomer mixtures, 0.6 (wt./wt.)% and 1 (wt./wt.)% sodium alginate in DIW were prepared and used as the DP, with oil as the CP. The DP rates for the 0.6% mixture were increased to between 3 μL/min to 5 μL/min to compensate for the increase in viscosity. However, the increments were kept at 0.1 μL/min. Similarly, the rates for the 1% mixture increased to between 5 μL/min and 7 μL/min, again with 0.1 μL/min increments. Images were taken again for every flow rate, and average diameter was plotted against DIW droplets. Average variance was also calculated for each concentration of sodium alginate. A mixture of 1.5% Span 80 and 3% calcium acetate (C4H6O4Ca) in soybean oil by weight was prepared and used as the CP. In addition, three solutions of sodium alginate (NaC6H7O6) in DIW were prepared, at 0.5%, 1%, and 1.5% by weight. Each mixture of sodium alginate was used as the DP, and the soybean oil mixture was used as the continuous phase. Capsules were created in the same way as droplets, with adjustments to stabilize droplet formation. The 0.5% sodium alginate mixture stabilized around a CFR of 1.78 mL/hr, and a dispersive rate of 2 μL/min. The 1% solution stabilized around a CFR of 4.27 mL/hr and a dispersive of 1.5 μL/min, and the 1.5% solution around a CFR of 3.91 mL/hr and a dispersive of 4 μL/min. For each level of sodium alginate, images of the formation of capsules with calcium alginate surfaces were taken, and the capsules were then collected in a collection vial. The capsules within the vial were then viewed under a microscope and imaged once immediately after creation and once five minutes later. Figure 2. A vapor phase deposition system. Air moves in from the right through tubing to create bubbles containing octadecyltrichlorosilane vapor. The pressure in the vial pushes the vapor through the two outlet tubes into the inlets of the microfluidic chip. Weilong Li, Teresa Petralli-Mallow, and Zhihong Nie Page 3 of 5 26 Results At each flow rate increment, four droplets were measured for diameter. The change in diameter between flow rates, average diameter at each flow rate, and variance at each flow rate we
What problem does this paper attempt to address?