Numerical Simulation of a Gas Film-cooled Flat Plate Channel

陆犇,李凌波,姜培学,李崇权
DOI: https://doi.org/10.3969/j.issn.1001-2060.2005.04.019
2005-01-01
Abstract:A numerical simulation was performed of the coupled heat transfer problem involving the three-dimensional convection heat exchange and heat conduction in a gas film-cooled flat plat channel without ribs and with 45o ribs. A non-structured network was adopted for network division. The turbulent flow model is of a SST k - ω one. A wall function method has been adopted for the near-wall location. The coupling of speed and pressure was solved by using a SIMPLEC algorithm. Through calculations obtained were for the gas film-cooled flat plate without ribs and with 45o ribs a flow field distribution and the average temperature and average heat exchange factor at the flat plate inner and outer surface. The calculation results indicate that the channel flow-field structure of the gas film-cooled flat plate with 45o ribs is relatively complicated. The surface average temperature of the flat plate is lower than that of the gas film-cooled flat plate without ribs. However, the cold and hot surface average heat exchange factor near the gas-film pore zone is higher than in the case when no ribs are provided. Furthermore, the presence of ribs is favorable for enhancing cold-air outward flow ratio.
What problem does this paper attempt to address?