Heat Transfer Coefficients of Forward and Backward Cylindrical Hole Film Cooling Using Transient IR Technique

Bo Shi,Xueyang Li,Jing Ren,Hongde Jiang
DOI: https://doi.org/10.1115/gt2017-64275
2017-01-01
Abstract:Film cooling has been an effective method to protect the blade from hot gas. Recent studies have demonstrated that backward injection arrangement with cylindrical hole can achieve a much more uniform cooling effects under high blowing ratios, compared to forward injection which is commonly utilized. However, there has been relatively few results of heat transfer rate distribution with backward injections. The present experiment investigates a flat plate cooled with forward and backward coolant injection. Experiments are performed in a low speed wind tunnel. The test flat plate features cylindrical holes either along stream direction or reverse of it. Transient thermal measurements are carried out for the film cooling plate with IR camera. Detailed distributions of heat transfer coefficient are obtained. A series of blowing ratios from 0.25 to 2.0 are investigated. Effects of backward injection on the surface heat transfer distributions are studied, and the results are presented and explained in this investigation.
What problem does this paper attempt to address?