NUMERICAL CALCULATION OF FLOW FIELD AT THE TIME OF RETROFITTING ELECTRIC PRECIPITATOR INTO A BAG TYPE DUST COLLECTOR

孙晓茗,项光明,姚强,由长福
DOI: https://doi.org/10.3969/j.issn.1002-3364.2005.07.005
2005-01-01
Abstract:After retrofitting an electric precipitator into a bag type dust collector, difficulty for organizing flow field and resistance enhancement may be brought about due to limited space. Directing against retrofit of an electric precipitator in one thermal power plant, the numerical simulation of flow field for a single gas flow in the bag type dust collector proper has been carried out by using structuralized / non-structuralized hybrid gridiron technology, porous medium model, and k-e turbulent model. Calculated results show that the back flow may occur in the filtrating chamber and in lower tank body under condition of non-reasonable design. Thereby, a nonuniform pressure field to be formed in the bag chamber. The velocity of fluid flowing through filtrating bags at the final stage of the bag chamber is greater than that of fluid flowing through filtrating bags in the front stage, hence, filtrating bags in the final stage are more easily to be worn and failed. In addition, the incident velocity of the fluid, and influence of baffle plate upon calculated result have also been analysed through numeric test method. These results have guiding significance for design and operation of the dust collector.