Pilot Studies on Reducing Energy Consumption of Submerged Membrane Bioreactor

WANG Meng-jie,WEI Chun-hai,HUANG Xia,WEN Xiang-hua,ZHANG Jian-xin,CUI Xi-long
DOI: https://doi.org/10.3321/j.issn:1000-6923.2005.03.010
2005-01-01
Abstract:A pilot-scale submerged membrane bioreactor with treating capacity of 15.6m3/d was developed on the basis of its structural optimization design according to the principle of air-lift internal-loop reactor. Economical aeration intensity of this installation was 96m3/(m2·h) according to hydrodynamic investigation. Through critical flux test under the condition of economical aeration intensity, critical flux region of the membrane was 30~35L/(m2·h) when the sludge concentration was less than 13g/L. Therefore the operation parameters of continuous motion of the pilot installation was determined and under the condition of sub-critical flux of 30L/(m2·h), stable motion of sewage treatment was realized. Energy consumption analysis indicated that the air-to-water ratio of the pilot reactor was 21:1 and the effective unit energy consumption was 0.42kW·h/m3.