Effect of current configuration on weld properties and microstructure in synchronised twin-wire pulsed MAG welding

Yin LIANG,Ji-luan PAN,Hua ZHANG,Pin LIU,Yao-gang WU
DOI: https://doi.org/10.13289/j.issn.1009-6264.2017.04.015
2017-01-01
Abstract:The welding of Q235 steel plates was carried out by anti-phase synchronized synergic-pulsed twin-wire M AG welding (MAG) method and the effect of the lead-trail wires welding currents in different configuration on properties and microstructure of the welded joints was investigated.The results show that the difference of the lead-trail welding currents affects the microstructure,strength and hardness of the welded joints.When there is no difference between the lead-trail welding currents,the arc interference of the two electrodes is the most serious.With the increasing of the currents difference,the change of microstructure will affect the hardness and width of the heat affected zone (HAZ).If the current difference is greater,the hardness of the HAZ decreases and the HAZ width increases.The experimental results show that at pulse-pulse hybrid power combination,two welding wires pulse presented alternative ignition in negative phase.When the current of the lead wire is higher than that of the trail wire in a range of 20 A,the arcs interference is relatively small and the arcs is stable,and the optimal hardness,weld size and microstructure of the welded joins are obtained.
What problem does this paper attempt to address?