Experimental Study on Micro ECM Variable Cross-sectional Hole by Variable Parameters

Liqiu YU,Guili LIU,Yong LI,Quancun KONG,Guodong LIU
DOI: https://doi.org/10.3969/j.issn.1009-279X.2017.03.007
2017-01-01
Abstract:To improve the shape accuracy of the high aspect ratio variable cross-sectional hole by micro electrochemical machining (ECM) ,the influences on the shape accuracy of the variable cross-sectional hole by the time interval of different parameters were analyzed and simulated. A method by changing electrical parameters was designed and implemented. Then the experiments on micro ECM variable cross-sectional hole by changing electrical parameters were carried out in 18CrNi8 workpiece with 1 mm thick. In addition,the holes with the diameter of 200~320 μm,aspect ratio of about 5,are fabricated. The results show that the average error of shape is 9 μm when the time interval is equal to 1 s and it is reduced by about 85% compared with other time intervals. It meets well the design requirements,meanwhile,the effectiveness of the machined method is verified.
What problem does this paper attempt to address?