EXPERIMENTAL STUDY AND CALCULATION METHOD ANALYSIS OF PULL-OUT RESISTANCE PERFORMANCE FOR SELF-TAPPING SCREWS IN S60 FRAME CURTAIN WALL SYSTEM

Bin Zeng,Cun Hui,Weichi Han,Yuanqing Wang,Bin Wang,Wei Tao
DOI: https://doi.org/10.13204/j.gyjz201511034
2015-01-01
Abstract:To study the pull-out resistance performance and calculation method of load-bearing capacity of self-tapping screws, the calculation methods of load-bearing capacity of self-tapping screws in AAMA T1R A9-91 Metal Curtain Wall Fasteners and Aluminum Design Manual 2010 were analyzed.The experiments about pull-out resistance performance of self-tapping screws whose depth into the groove were 11 mm, 12 mm, 13 mm and 14 mm respectively were carried out.The problems of thermal barrier strip and lateral stiffness of notches in practical engineering were solved.The results showed that the results of experiments and those of calculation by AAMA T1R A9-91 matched to each other.With the increase of the depth into the groove of the self-tapping screws, the load-bearing capacity of pull-out resistance was increased.The suggested calculation formula of the load-bearing capacity of the pull-out resistance of self-tapping screws was also given.
What problem does this paper attempt to address?