Design and Experimental Study of an Indirect Heat Pump Distillation System for Treating High-Concentration Saline Wastewater

Jingxiang Lin,Guoliang Qin,Cheng Jia
DOI: https://doi.org/10.5004/dwt.2020.25177
IF: 1.1
2020-01-01
Desalination and Water Treatment
Abstract:Conventional distillation systems such as multi-effect evaporation and multi-stage flash evaporation are subject to problems of high energy consumption and additional corollary equipment, and energy-efficient mechanical vapor re-compression (MVR) systems have problems of compressor size and cost. An indirect heat pump distillation system for treating high-concentration saline wastewater is developed that consists of a refrigerant heat pump system and a double-effect forced circulation system. Using refrigerant as the heat pump working fluid can significantly reduce the volume flow rate of the compressor design under the same compressor outlet energy head. Through a comparative analysis based on the first law of thermodynamics, it was found that using the R-22 refrigerant and the countercurrent feeding method can achieve better results than those achieved by R-134a and the downstream feeding method. A temperature of 25 degrees C is the optimum feeding temperature, and it allows the system to have a better compressor performance and a smaller heat transfer area. A comparison of the experimental and exergy analysis results shows that the energy efficiency of the designed system is close to that of the MVR system in the literature, and the designed system has advantages in both compressor selection and system operation.