The Influence of Successive Irradiation of He and H Ions on the Structure, Morphology and Property of Metallic Glass Fe80B13Si7

Xiaonan Zhang,Tong Guan,Lisong Zhang,Xianxiu Mei,Younian Wang
DOI: https://doi.org/10.1016/j.surfcoat.2020.125609
IF: 4.865
2020-01-01
Surface and Coatings Technology
Abstract:500 keV He ions and 250 keV H ions was used to irradiate the metallic glass Fe80B13Si7. When the fluence increased to 2 x 10(17) He ions/cm(2) + 1 x 10(18)H ions/cm(2) or 1 x 10(18) He ions/cm(2) + 5 x 10(17)H ions/cm(2), no crystallization or obvious surface damage appeared in the metallic glass. Compared with the case of He ions or H ions irradiation, the successive irradiation of both ions roughened the surface of the Fe-based metallic glass. Under the successive irradiation, the He bubble layer thickened due to the diffusion of bubbles, and the size of bubbles decreased while the number density increased. The metallic glass Fe80B13Si7 still maintained good soft magnetic property under the successive irradiation, while its saturation magnetic induction intensity and coercive force changed slightly.
What problem does this paper attempt to address?