Abstract:An electrochemical impedancemetric NO2 sensor was prepared with Cr impregnated spinel-oxide CoCrFeO4 as a sensing electrode and La9.4Ba0.6Si5.9W0.1O26.8 as an electrolyte. A La9.4Ba0.6Si5.9W0.1O26.8 porous layer was made through screen printing, and a CoCrFeO4 sensing material was prepared through wet impregnation. The sensitivity of the NO2 sensor was tested using an electrochemical workstation, and phase angle theta was used as sensitive signals. Cr impregnated CoFe2O4 sensor exhibited higher sensitivity and shorter response time compared to CoFe2O4 sensor. The optimum temperature and test frequency are 550 degrees C and 0.1 Hz where the sensor shows high sensitivity and stability. A good linear relationship was observed between the theta sensitive signal and the logarithm of NO2 concentrations. The sensor had a sensitivity of 9.1123 and showed a good anti-interference performance for CO2, CH4, and H-2. (C) 2020 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.
What problem does this paper attempt to address?