Vapor Pressure of Aqueous HCOOK Solution As Working Fluids of an Absorption Heat Transformer at High Temperature

Shaozhi Zhang,Jielin Luo,Ruirui Zheng,Xiaohui Wang,Guangming Chen,Qin Wang
DOI: https://doi.org/10.1021/acs.jced.9b00745
IF: 3.119
2020-01-01
Journal of Chemical & Engineering Data
Abstract:Aqueous potassium formate solution is regarded as a potential working fluid of an absorption heat transformer (AHT) because of its noncorrosive and biodegradable characteristics. The vapor pressure of working fluids is an important property for application in an absorption cycle. However, current experimental data are mostly limited to temperature and concentration ranges that are suitable for a dehumidification system. Thus, more accurate data of vapor pressure are anticipated. In this paper, the equilibrium vapor pressures of aqueous HCOOK solution were measured with a static method in the temperature range from 323.15 to 373.15 K. The mass concentration of HCOOK varied from 10 to 70%. The measured data were compared with the estimated values of a referenced chemical engineering property database (Aspen Plus). A relatively large mean absolute relative deviation (MARD) of 13.27% was found. The data were then correlated with a modified Antoine equation, and the MARD was reduced to 0.45%. The thermodynamic performance of aqueous HCOOK solution for AHT was estimated for a typical cycle.