Effectiveness Factors for a Partially Wetted Catalyst Based on the Rivulet Flow Model

Yanling Tang,Meichen Chen,Zhenmin Cheng,Tao Yang,Bo Chen,Hailong Ge,Xiangchen Fang
DOI: https://doi.org/10.1016/j.ces.2020.115515
IF: 4.7
2020-01-01
Chemical Engineering Science
Abstract:Partial wetting is a common phenomenon in a trickle bed reactor, which causes nonuniform mass transfer flux at the external surface of the catalyst. Previous work on effectiveness factor for a partially wetted catalyst are mainly based on the assumption that the spherical catalyst is wetted by a liquid film. In fact, it is only true when the liquid-solid contact angle is very small. In most situations, rivulet flow prevails. The purpose of the article is to calculate effectiveness factors for both gas-limited and liquid-limited reactions under the two wetting modes by using finite element method (FEM). The effects of wetting efficiency, Biot number, and Thiele modulus on effectiveness factors are investigated. On the basis of the FEM results, the intrinsic reason for the variation of effectiveness factors with respect to wetting efficiency is revealed, and good agreements are observed between this work and the conventional models.
What problem does this paper attempt to address?