Condition Monitoring the Forced Air Cooling System Using the Natural Frequency of Thermal Network

Jun Zhang,Xiong Du,Rui Du,Pengju Sun
DOI: https://doi.org/10.1109/ecce.2019.8912553
2019-01-01
Abstract:The forced air cooling system plays an important role in the safe operation of power converters. Condition monitoring its health status can improve the reliability of power converter and reduce the cost of unscheduled maintenance due to over-heating. This paper used the natural frequency of thermal network as an indicator to monitor the aging process of cooling system. We show that the degradation of cooling system can be monitored by detecting the variation of natural frequency. Experimental tests on a three-phase DC/AC converter with forced air cooling system are performed to verify the effectiveness of proposed method. This method is simple to implement and does not need to measure the power loss. Moreover, it enables the concurrent monitoring of multiple components in the cooling system.
What problem does this paper attempt to address?