Performance Analysis of Linear Compressor Using R290 for Commercial Refrigerator

Huiming Zou,Xuan Li,Mingsheng Tang,Changqing Tian,Xu Chen
DOI: https://doi.org/10.1016/j.ijrefrig.2019.10.002
IF: 4.14
2020-01-01
International Journal of Refrigeration
Abstract:Linear compressor is a promising alternative for commercial refrigerator using R290. In this paper, a design program of linear compressor is set up. The leakage mass flow rate is modeled based on small hole leakage principle. The errors of the model are within 10%. The cooling performance of linear compressor with different piston diameter for commercial referigerator using R290 is analyzed. As the linear compressor is set to have the same swept volume, small piston diameter is beneficial to the COP improvement, but has a few decrease of cooling capacity. As the linear compressor is set to have the same cooling capacity by adjusting power frequency, COP of the linear compressor with piston diameter of 28 mm and 30 mm gets a little decrease because the power frequency deviates from the inherent frequency. The optimal piston diameter of 12 CC swept volume for the commercial refrigeration is suggested to be from 30 mm to 32 mm. (C) 2019 Elsevier Ltd and IIR. All rights reserved.
What problem does this paper attempt to address?