Dosimetric Comparison of Robotic Radiosurgery and VMAT Delivering Stereotactic Ablative Body Radiation Therapy to Small Renal Cancer

R. Peng,H. Wang,J. Li,R. Yang,J. Wang
DOI: https://doi.org/10.1016/j.ijrobp.2019.06.1956
2019-01-01
Abstract:The role of Stereotactic Ablative Body Radiation Therapy (SABR) to the primary renal cancer is evolving for patients who cannot be treated by surgical procedure for variant reasons. This study compared the dosimetric results of SABR for small renal cancer using robotic radiosurgery and Volume Modulated Arc Therapy (VMAT) based treatment planning. Ten renal cancer patients with the largest diameter of tumor less than 4cm treated in our institution were enrolled in this study. The abdominal CT scans of those patients were prospectively collected and the slice thickness was set to 0.75mm. For each patient, GTV was defined as the tumor. PTV was generated by expanding GTV by 3mm in three dimensional directions and a prescription dose of 48Gy in 3 fractions was given to the PTV. Two plans based on the robotic radiosurgery and VMAT platforms were designed. The volume-dose constraints were based on TG101 report. The dosimetric parameters of targets and OARs were collected and compared by paired sample Wilcoxon's rank-sum test. The median V100 of PTV was 95.43% for robotic radiosurgery and 95.00% for VMAT (p = 0.333), respectively. The CI and HI were not significantly different. Eight plans reached all the volume-dose constraints, while volume-dose of 1 plan of robotic radiosurgery (Dmax of intestine) and 2 plans of VMAT (Dmax of intestine and Dmax of colon) failed to fulfil the all the requirements, which was due to small distance between intestine and the tumor. Compared to VMAT, robotic radiosurgery reduced the high dose to the intestine and colon. Dmax and D5cc to the intestine were lower in robotic radiosurgery plan. D700cc and Dmean to the liver were a little higher in the robotic radiosurgery plan. Details of the results were provided in the table. This dosimetric study shows that both robotic radiosurgery and VMAT provide good dose coverage of target for delivering SABR to the small renal cancer in most conditions, while a small benefit of bowel and colon is seen when comparing robotic radiosurgery to VMAT. For institutions where robotic radiosurgery and VMAT are both available, robotic radiosurgery might be a better choice to deliver SABR to small renal cancer.Abstract 2590; Table 1The dosimetric parameters of robotic radiosurgery and VMAT plansParameters (median)CKVMATp valuePTV V100%95.4395.000.333GTV V100%100.00100.000.273CI1.161.220.153HI1.301.240.074D10cc-stomach (cGy)934.25529.130.144D5cc-stomach (cGy)1049.00594.790.144Dmax-intestine (cGy)1183.811513.950.007D20cc- intestine (cGy)619.35681.300.878D10cc- intestine (cGy)719.10898.330.093D5cc-bowel (cGy)802.051040.000.013Dmax-colon (cGy)1706.271923.950.050D20cc-colon (cGy)758.20658.340.889D10cc-colon (cGy)895.25981.080.327D5cc-colon (cGy)987.601130.240.123D700cc-liver (cGy)44.106.180.008Dmean-liver (cGy)106.3475.000.005D1cc-Cord (cGy)426.40536.150.203D0.5cc-Cord (cGy)463.35558.440.241Dmax-Cord (cGy)547.42609.950.575V14Gy-contralateral kidney (cGy)0.000.001.000Dmean-contralateral kidney (cGy)92.63148.210.878 Open table in a new tab
What problem does this paper attempt to address?