Sparing Organs at Risk with Simultaneous Integrated Boost Volumetric Modulated Arc Therapy for Locally Advanced Non-Small Cell Lung Cancer: an Automatic Treatment Planning Study

Daquan Wang,Jiayun Chen,Xiaodong Zhang,Tao Zhang,Luhua Wang,Qinfu Feng,Zongmei Zhou,Jianrong Dai,Nan Bi
DOI: https://doi.org/10.2147/cmar.s273197
2020-01-01
Cancer Management and Research
Abstract:BACKGROUND:The technique of simultaneous integrated boost volumetric modulated arc therapy (SIB-VMAT) has been widely used in locally advanced non-small cell lung cancer; however, its dosimetric advantages are seldom reported. This study aimed to quantify dosimetric advantages of SIB-VMAT.METHODS:Forty patients with stage III non-small cell lung cancer in our hospital were retrospectively included. SIB-VMAT and conventional VMAT (C-VMAT) plans were generated for every patient using the automatic treatment planning system. A reduced dose was delivered to PTV in SIB-VAMT plans compared to C-VMAT plans (50.4Gy vs 60Gy). The prescribed dose was 50.4 Gy in 28 fractions to PTV and 59.92 Gy in 28 fractions to PGTV in SIB-VMAT plans, while 60 Gy in 30 fractions to PTV in C-VMAT plans. Dose-volume metrics of PTV, total lung, heart, esophagus and spinal cord were recorded. The quality score was used to evaluate organs at risk (OAR) protection for two type prescription plans.RESULTS:Conformal coverage of the targets (PGTV/PTV) by 95% of the prescription dose was well achieved in radiation plans. SIB-VMAT plans achieved significantly higher quality score than C-VMAT plans (Mean: 68.15±13.32 vs 49.15±13.35, P<0.001). More plans scored above sixty in SIB-VMAT group compared to C-VMAT group (72.5% vs 20%, P<0.001). Notable reductions in mean dose, V30, V40 and V50 of total lung were observed in SIB-VMAT plans compared to C-VMAT plans, with median decreased proportions of 6.5%, 8.7%, 19.6% and 32.1%, respectively. Statistically significant decrease in heart V30 and V40 was also achieved in SIB-VMAT plans, with median decreased proportions of 26.1% and 38.8%. SIB-VMAT plans achieved significant reductions in the maximum doses to both esophagus and spinal cord. Patients with CTV/(GTV+GTVnd) ≥8.6 showed more notable decrease in total lung V50 (median, 33.6% vs 28.8%, P=0.001) in SIB-VMAT plans compared to those with the ratio being less than 8.6.CONCLUSION:SIB-VMAT technique could lead to a substantial sparing of normal organs, including lung, heart, esophagus and cord, mainly through reducing high and inter-median dose exposure. Patients with CTV/(GTV+GTVnd) ≥8.6 might benefit more from SIB-VMAT.
What problem does this paper attempt to address?