Single isocenter versus dual isocenter treatment using flattening filter‐free and jaw‐tracking volumetrically modulated arc therapy for boot‐shaped lung cancer: Evaluation of dosimetric and feasibility

Lei Zhang,Hang Cheng,Fenglei Du,Kainan Shao,Shiming Zheng,Yiwei Yang,Guoping Shan
DOI: https://doi.org/10.1002/acm2.14292
2024-01-30
Journal of Applied Clinical Medical Physics
Abstract:Background To determine whether a dual‐isocenter volumetrically modulated arc therapy (VMAT) technique results in lower normal pulmonary dosage compared to a traditional single isocenter technique for boot‐shaped lung cancer. Methods A cohort of 15 patients with advanced peripheral or central lung cancer who had metastases in the mediastinum and supraclavicular lymph nodes was randomly selected for this retrospective study. VMAT plans were generated for each patient using two different beam alignment techniques with the 6‐MV flattening filter‐free (FFF) photon beam: single‐isocenter jaw‐tracking VMAT based on the Varian TrueBeam linear accelerator (S‐TV), and dual‐isocenter VMAT based on both TrueBeam (D‐TV) and Halcyon linear accelerator (D‐HV). For all 45 treatment plans, planning target volume (PTV) dose coverage, conformity/homogeneity index (CI/HI), mean heart dose (MHD), mean lung dose (MLD) and the total lung tissue receiving 5, 20, 30 Gy (V5, V20, V30) were evaluated. The monitor units (MUs), delivery time, and plan quality assurance (QA) results were recorded. Results The quality of the objectives of the three plans was comparable to each other. In comparison with S‐TV, D‐TV and D‐HV improved the CI and HI of the PTV (p
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?