Characteristic Analysis of Unbalanced Magnetic Pull Caused by Non-salient Pole Synchronous Generator Rotor Inter-turn Short Circuit Fault

LI Yang,HAO Liangliang,SUN Yuguang,WANG Xiangheng,WU Junyong,ZHANG Guangtao
DOI: https://doi.org/10.7500/aeps20150520005
2016-01-01
Abstract:The rotor winding inter-turn short circuit fault will generate an even number of and fractional harmonic unbalanced current components related to the number of pole-pairs and stator winding configurations in stator loops.Considering the above situation,the expression of the unbalanced magnetic pull(UMP)in the coordinate axis direction of stator Cartesian coordinates is derived based on the harmonic magnetomotive force (MMF) caused by the harmonic component of unbalanced current. Secondly,according to the characteristics of the stator and rotor MMF,the expression of frequency of UMP is obtained and a complete characteristic analytic method for UMP under a fault is formed.This method has been applied in the rotor inter-turn short circuit fault analysis in non-salient pole generator prototypes with a different number of pole-pairs.The numerical result of the rotor electromagnetic force in a fault is calculated by the field circuit coupling of ANSOFT software.Simulation results are consistent with the findings of theoretical analysis,which proves the correctness of this method.Both theoretical analysis and simulation results show that generators with a different number of pole-pairs and stator winding configurations will have UMP with different harmonic characteristics,which lays the foundation for fault monitoring by merging electro-mechanical information.
What problem does this paper attempt to address?