Abstract:Arc voltage measurement is an important method to study the characteristics of breaking arc.To eliminate the voltage drop caused by the inner conductors of high voltage circuit breakers,in this paper,an eliminating method of the additional pressure drop is proposed,and an arc voltage measurement device is developed.Experimental results show that the arc voltage measurement device is suitable for the rated voltage of 12~126 kV high voltage circuit breakers.Furthermore,the measurement of arc voltage by using the proposed method is efficient and convenient comparing with the existing methods that need an additional test with short circuit current passing through the test objects.