A Wireless Multi-Channel Peripheral Nerve Signal Acquisition System-on-Chip

Kian Ann Ng,Chao Yuan,Astrid Rusly,Anh-Tuan Do,Bin Zhao,Shih-Chiang Liu,Wendy Yen Xian Peh,Xin Yuan Thow,Kai Voges,Sanghoon Lee,Gil Gerald Lasam Gammad,Khay-Wai Leong,John S. Ho,Silvia Bossi,Gemma Taverni,Annarita Cutrone,Shih-Cheng Yen,Yong Ping Xu
DOI: https://doi.org/10.1109/jssc.2019.2909158
IF: 5.4
2019-01-01
IEEE Journal of Solid-State Circuits
Abstract:The adoption of chronic implantable peripheral nerve-based prosthetic devices is currently hampered by the lack of a highly integrated neural signal acquisition system-on-chip (SoC). We report a ten-channel peripheral nervous system (PNS) electroneurogram (ENG) signal acquisition SoC within an implantable package. Requiring only four off-chip capacitors, this SoC can be co-encapsulated with flexible nerve electrodes and a resonant coil antenna to form a 3.4 cm <sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">3</sup> and 3.9 g implantable device for chronic ENG acquisition. This SoC is inductively powered and controlled through a resonant coil at 22 MHz and transmits the digitized neural signal through a near-infrared LED (NIR-LED). Fabricated in 0.18- <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{m}$ </tex-math></inline-formula> CMOS, each amplifier channel exhibits an input referred noise of 1.9 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\mu \text{V}_{\mathbf {rms}}$ </tex-math></inline-formula> and a noise efficiency factor (NEF) of 4.0 within the signal bandwidth of 5.5 kHz. Each amplifier channel within the SoC is digitized with 10-bit resolution at 17.5 ksps, and the total power consumption (SoC and NIR-LED) is 4.4 mW when the NIR-LED is driven at 3 Mb/s. An electrode impedance measurement circuit with <10% magnitude and <8° angle error for measuring impedances up to 1 <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$\text{M}\Omega $ </tex-math></inline-formula> is also incorporated in this SoC. This wireless, low noise ENG acquisition SoC package has been validated <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">in vivo</italic> while implanted on a rodent to acquire ENG from its sciatic nerve.
What problem does this paper attempt to address?