Microbial Fuel Cell Using UASB As Anode and Effects of Hydrogen Peroxide on Treatment Efficiency

Z. A. Bhatti,A. Waheed,F. Maqbool,Y. G. Zhao,S. Qayyum,Q. Mehmood,F. Faridullah
DOI: https://doi.org/10.3103/s1063455x1901003x
2019-01-01
Journal of Water Chemistry and Technology
Abstract:Dual chambered continuous up-flow microbial fuel cell (MFC) was used to check the effect of controlled temperature and addition of different hydrogen peroxide (H2O2) doses on bioelectricity production. MFC-1 and MFC-2 showed 77 and 89% of COD removal efficiency, respectively, while same amount 13.4% of coulombic efficiency under continuous operation mode were produced by both reactors. Oxygenation of cathode chambers of both MFC with 5 mL of H2O2 resulted in higher values of potential difference and current, 1100 mV and 0.6 mA in MFC-1 and 674 mV and 0.32 mA in MFC-2. Higher power density of 166 Pd·cm−2 was produced by reactor 1 than 75 Pd·cm−2 from reactor 2. Result showed that control temperature of 35°C had lowered down the bioelectricity production while increased the COD removal. The use of H2O2 for oxygenation was found to improve the voltage and current production and stability of MFC.
What problem does this paper attempt to address?