Aliyu Ishaq,Mohd Ismid Mohd Said,Shamila Binti Azman,Mohammed Rajab Houmsi,Abubakar Sadiq Isah,Zainab Toyin Jagun,Shamsuddeen Jumande Mohammad,Al−Amin Danladi Bello,Umar Alfa Abubakar
Abstract:Abstract Microbial fuel cells (MFCs), hailed as a promising technology, hold the potential to combat various wastewater pollutants while simultaneously converting their chemical energy into electricity through biocatalysts. This study explores the applicability of a dual compartment MFC (DC-MFC) under varying conditions, targeting the removal of chemical oxygen demand (COD) from landfill leachate and electricity generation. In this setup, anaerobic sludge from a wastewater treatment plant serves as the inoculum in the anode compartment of the MFC, with a Nafion117 membrane acting as the separator between MFC units. The cathode compartments are filled with distilled water and continually aerated for 24 h to enhance air supply. The study assesses the MFC’s performance across different COD concentrations, focusing on COD removal, power generation, and Coulombic efficiency. The findings reveal that COD removal efficiency is notably enhanced at higher concentrations of organic matter. Specifically, at a COD concentration of 3325.0 mg L −1 , the MFC exhibited the highest COD removal efficiency (89%) and maximum power density (339.41 mWm −2 ), accompanied by a Coulombic efficiency of 25.5%. However, as the initial substrate concentration increased to 3825 mg L −1 , the efficiency decreased to 72%, with a Coulombic efficiency of 13.56% and a power density of 262.34 mWm −2 . Optical density levels increased due to bacterial growth at ambient temperature and neutral pH, reflecting the dynamic microbial response within the system.
What problem does this paper attempt to address?
The main problem this paper attempts to address is the treatment of chemical oxygen demand (COD) in landfill leachate using microbial fuel cell (MFC) technology while simultaneously generating electricity. Specifically, the study aims to explore the performance of a dual-chamber MFC (DC-MFC) in terms of COD removal and power generation under different COD concentration conditions.
### Research Background
- **Environmental Issues**: Landfill leachate contains complex organic pollutants that are difficult to remove effectively using traditional treatment methods, and the treatment costs are high.
- **Energy Demand**: With the increasing demand for renewable energy, using bioelectrochemical systems (such as MFCs) to treat wastewater and generate electricity simultaneously has become a promising technology.
### Research Objectives
- **COD Removal**: Evaluate the efficiency of MFC in removing COD from landfill leachate under different COD concentrations.
- **Power Generation**: Measure the power output and coulombic efficiency of MFC under different COD concentrations.
- **Microbial Response**: Analyze the impact of different COD concentrations on the microbial community within the MFC, particularly bacterial growth and biofilm formation.
### Research Methods
- **Experimental Setup**: Use a dual-chamber MFC, with the anode chamber filled with anaerobic sludge as the inoculum source, and the cathode chamber filled with distilled water and continuously aerated.
- **Experimental Design**: Assess the performance of the MFC by varying the influent COD concentrations (1325 mg/L, 1825 mg/L, 2325 mg/L, 2825 mg/L, 3325 mg/L, and 3825 mg/L).
- **Data Collection**: Record parameters such as voltage, current, and power density, and calculate coulombic efficiency.
### Key Findings
- **COD Removal Efficiency**: At a COD concentration of 3325 mg/L, the MFC achieved the highest COD removal efficiency of 89%, with a maximum power density of 339.41 mW/m² and a coulombic efficiency of 25.5%.
- **Impact of High COD Concentration**: When the initial substrate concentration increased to 3825 mg/L, the COD removal efficiency decreased to 72%, the coulombic efficiency dropped to 13.56%, and the power density decreased to 262.34 mW/m².
- **Microbial Response**: Under suitable temperature and neutral pH conditions, bacterial growth was significant, with an increase in optical density levels, reflecting the dynamic changes of the microbial community within the system.
### Conclusion
This study demonstrates the potential of MFC in treating landfill leachate, particularly in terms of COD removal and power generation. However, excessively high COD concentrations may reduce system performance, necessitating further optimization to improve overall efficiency. Additionally, the study reveals the impact of different COD concentrations on the microbial community, providing valuable insights for further optimization of MFC systems.