Accuracy of the Parallel Reset Mechanism in a Wind Tunnel Balance Calibration System

GUAN Liwen,CHEN Huang,FU Meng
DOI: https://doi.org/10.16511/j.cnki.qhdxxb.2018.25.011
2018-01-01
Abstract:A 6-DOF (degree of freedom) parallel machine was used as the reset mechanism in a wind tunnel balance calibration system because of its simple structure and stiffness.A model was developed using the D-H (Denavit-Hartenberg) convention to analyze inaccuracies in the reset mechanism caused by joint manufacturing tolerances.In this model,each closed-loop kinematic chain was treated as a RRRPRR chain.The effects of the joint tolerances and structural parameters on the kinematic accuracy were calculated based on Qusai-Newton method.Simulations indicate that the inaccuracy is on the same order of magnitude as the joint offsets.A principle is given to determine the structural parameters needed to improve the accuracy of this type of reset system.
What problem does this paper attempt to address?