Three-dimensional PEDOT Composite Based Electrochemical Sensor for Sensitive Detection of Chlorophenol

Qingyun Tian,Jingkun Xu,Yinxiu Zuo,Yingying Li,Jialing Zhang,Yaoyi Zhou,Xuemin Duan,Limin Lu,Haiyan Jia,Quan Xu,Yongfang Yu
DOI: https://doi.org/10.1016/j.jelechem.2019.01.055
IF: 4.598
2019-01-01
Journal of Electroanalytical Chemistry
Abstract:In this work, electrode based on poly(3,4-ethylenedioxythiophene) (PEDOT) was employed for the fabrication of an efficient sensor for 4-chloro-3-methylphenol (PCMC) detection. To improve the dispersity and increase the specific surface area of PEDOT, core-shell structured UiO-66-NH2@PEDOT was designed by in-situ oxidation method using Zr-based metal-organic framework (UiO-66-NH2) as template. In addition, to achieve a further increased active surface area and electron transfer rate of the modified materials, graphene aerogel (GA) was utilized as substrate material for the assembly of UiO-66-NH2@PEDOT. Then, the obtained UiO-66-NH2@ PEDOT/GA modified electrode was employed as an electrochemical sensor for PCMC detection. Experiment parameters, such as pH value of acetate buffer solution and accumulation time, were optimized in detail. Under the optimized experiment condition, the UiO-66-NH2@PEDOT/GA electrode showed a good linear range of 0.6–18μM, as well as a low detection limit of 0.2μM (S/N=3). The UiO-66-NH2@PEDOT/GA electrode was applied toward the detection of PCMC in tap water with good recovery. All these features suggest that the prepared PEDOT-based composite could serve as a promising sensing platform for monitoring water pollutants.
What problem does this paper attempt to address?