Treatment of electroplating wastewater containing nickel ions with ceramic membranes
zhang jinbin,ceng jianxian,zhang xuejun,shen shaohua,yu xie,qian chaohui,zhang peng,tian jun
2016-01-01
Abstract:The microfiltration processes of electroplating wastewater containing nickel ions were studied with ceramic membranes with average pore diameters of 0. 5 μm and 0. 8 μm at p H 9. The effects of operating time,trans-membrane pressure,cross-flow velocity,temperature,and volume concentration factor on permeate flux and nickel rejection were investigated. Next,the cleaning of fouled membranes was studied,as was the mathematical model of the microfiltration process. The results showed that with increasing operating time,permeate fluxes decreased rapidly to a steady value. Steady-state fluxes were enhanced with increasing trans-membrane pressure or cross-flow velocity,and then remained constant. Steady-state fluxes were enhanced with increasing temperature.Optimum operating parameters for the 0. 8 μm membrane were trans-membrane pressure of 0. 12 MPa,cross-flow velocity of 3. 0 m / s,and temperature of 30 ℃. Optimum operating parameters for the 0. 5 μm membrane were trans-membrane pressure of 0. 14 MPa,cross-flow velocity of 3. 4 m / s,and temperature of 30 ℃. In the process of concentration,permeate fluxes decreased to a steady value and then decreased rapidly,and the nickel rejections were about 99%. Permeate fluxes could be recovered effectively to new membrane fluxes of 98% for a 0. 8 μm membrane and 97. 5% for a 0. 5 μm membrane by using 0. 15% hydrochloric acid. In addition,the modified completely blocked model can describe the microfiltration processes.