Near-infrared Detection of Straw Cellulose by Orthogonal Signal Correction and Partial Least Squares

Qingming Kong,Zhongbin Su,Weizheng Shen,Mingming Han,Bohan Li,Xudong Wang
DOI: https://doi.org/10.14257/ijmue.2015.10.5.23
2015-01-01
International Journal of Multimedia and Ubiquitous Engineering
Abstract:Orthogonal signal correction (OSC)and partial least squares(PLS)were used during the pretreatment of straw to reduce environmental noise and prediction models were established for near-infrared detection of straw cellulose. Tests were run with soybean stalk as the object of study. Test results indicated that compared to a model established using a traditional denoising method, the determination coefficients for calibration set models established by second derivative+smoothing and OSC were 0.9318595 and 0.9328905 respectively while the root mean square error for calibration (RMSEC) were 0.6762902 and 0.6696454. For an OSC-PLS regression model with a factor of 8, the relative standard deviation of a prediction model was less than 5%. In the OSC denoising process, the root mean square error fluctuated with the increasing number of PLS factors. Compared to the second derivative-smoothing denoising, OSC-PLS denoising removed the non-correlated variation from spectra and improved interpretation ability of variation while the analysis and convergence were expedited. It was therefore concluded that OSC-PLS denoising could be used to realize the rapid and accurate near-infrared detection of straw cellulose.
What problem does this paper attempt to address?