Metal Cluster-Based Electrochemical Biosensing System for Detecting Epithelial-to-Mesenchymal Transition
Ying Han,Cuicui Qiu,Jiaojiao Li,Fuping Gao,Qing Yuan,Yuhua Tang,Wenchao Niu,Xiayan Wang,Xueyun Gao,Liang Gao
DOI: https://doi.org/10.1021/acssensors.1c00339
IF: 8.9
2021-05-27
ACS Sensors
Abstract:N-cadherin serves as an important oncobiomarker of epithelial-to-mesenchymal transition (EMT) progression, which identifies invasion and metastasis of malignant tumor cells. Although many efforts have been devoted to quantitative detection of N-cadherin, efforts to analyzing the protein of interest at intact cellular levels are scarce. Herein, a metal cluster-based electrochemical biosensing system is developed to determine the expressing levels of N-cadherin during the EMT process of tumor cells. To be specific, a peptide with a unique sequence and function is designed as a reductant and an anchor to synthesize metal clusters in a precise manner. Consequently, peptide-modified metal clusters possess N-cadherin-targeting, photoluminescence, and electrocatalytic properties. Especially, the redox-active metal clusters function as both an electron-transfer mediator and an electronic conductor for enhanced electrochemical sensing. These favorable features enable them as a rapid, sensitive, and reliable whole-cell biosensor, which integrates the fluorescence and electrochemical signals. This cytosensor can accurately quantify the expression levels of N-cadherin on at least 5000 tumor cells. Further, the current signals of model cancer cells gradually increase with EMT progression, indicating tumor cell-type evolution. Our study represents the advanced bioprobe and analytical methods for accurate quantitation of a biomarker to identify tumor progression.The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acssensors.1c00339?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acssensors.1c00339</a>.The formula of quantitative calculation, the stability of AuCs, optimization of conditions of cells labeled with AuCs, optimization of electrochemical test conditions, the influence of pH changes on the current signal, the characterization of the surface morphology and the structure of the modified electrode, the effect of pure cells on the current signal, and quantitative analysis of N-cadherin in CaSki cells with lower N-cadherin levels (<a class="ext-link" href="/doi/suppl/10.1021/acssensors.1c00339/suppl_file/se1c00339_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
chemistry, multidisciplinary, analytical,nanoscience & nanotechnology