One-year operation of 1000-L modularized microbial fuel cell for municipal wastewater treatment

Peng Liang,Rui Duan,Yong Jiang,Xiaoyuan Zhang,Yong Qiu,Xia Huang
DOI: https://doi.org/10.1016/j.watres.2018.04.066
IF: 12.8
2018-01-01
Water Research
Abstract:This study constructed a 1000 L modularized MFC system, the largest volume so far, to treat practical municipal wastewater. This MFC system was operated under two different water flow connections in two municipal wastewater treatment plants (MWTP) for more than one year to test their treating abilities for wastewater with both low (average 80 mg L−1) and high initial COD concentration (average 250 mg L−1). The COD concentration in the effluent from the MFC system remained below 50 mg L−1 with a removal rate of 70–90%, which stably met the level A of the first class in discharge standard of pollutants for MWTP of China. A maximum power density of 125 W m−3 (7.58 W m−2) was generated when the MFC system was fed with artificial wastewater, while it lay in a range of 7–60 W m−3 (0.42–3.64 W m−2) when treating municipal wastewater. The energy recovery of 0.033 ± 0.005 kWh per m3 of municipal wastewater was achieved, with a hydraulic retention time (HRT) of 2 h.
What problem does this paper attempt to address?