Study on Enhanced Nitrogen and Phosphorus Removal in Baffled Biological Aerated Filter
Jian ZHOU,Ming-yue LIU,Teng-rui LONG,Qiang HE,Zhi-gang LI,Di-qing WU
DOI: https://doi.org/10.3321/j.issn:1000-4602.2007.23.003
2007-01-01
Abstract:Aimed at the problem of low nitrogen and phosphorus removal efficiencies in conventional biological aerated filter,the influence of air/water ratio and intermittent aeration mode on nitrogen and phosphorus removal efficiencies in baffled biological aerated filter was investigated in combination with the productive experiment of demonstration project of wastewater treatment in Xinsheng Town of Chongqing City.The results show that under the conditions of temperature 13 to 18 ℃,organic load 0.86 kg/(m3·d),HRT 8 h,air/water ratio 5 ∶1 and intermittent aeration(aeration 1.0 h and non-aeration 1.5 h),the effluent COD,NH3-N,TN and TP are 23.3 mg/L,10.12 mg/L,16.30 mg/L and 0.46 mg/L respectively,and their removal efficiencies are 80.5%,47.4%,43.7% and 77.0% respectively.The effluent quality reaches the Ⅰ-B criteria specified in the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant(GB 18918-2002).