Testing Methods for Counting Efficiency of EPA/HEPA/ULPA Filter Media

ZHANG Zhenzhong,WEI Jiying,JIANG Feng,YU Tao
DOI: https://doi.org/10.16511/j.cnki.qhdxxb.2010.03.014
2010-01-01
Abstract:A clear understanding of four counting methods used measure the efficiency of filter media,the 0.1-0.2 μm,0.2-0.3 μm,quasi-monodisperse and most penetrating particle size(MPPS) methods,is needed to develop the filter testing industry.This study analyzes the filtration efficiencies of seven classes of filter media.The theoretical calculations involve five filtration velocities,three aerosol generators and the four counting methods.The results show that the dioctyl phthalate(DOP) aerosol is more suitable for efficiency testing of counting method with the 0.1-0.2 μm or 0.2-0.3 μm methods than NaCl aerosol and that the quasi-monodisperse method is more suitable for efficiency testing of counting method than 0.1-0.2 μm and 0.2-0.3 μm methods.
What problem does this paper attempt to address?