Relationship Between NaCl Aerosol Size Distribution and Testing Efficiency for the Sodium Flame Method

ZHANG Zhenzhong,JIANG Feng,YE Suisheng,CHEN Liang,WEI Jiying,FAN Guifang
DOI: https://doi.org/10.3321/j.issn:1000-0054.2009.03.022
2009-01-01
Abstract:The sodium flame method is one of the most important methods for HEPA media filtration efficiency measurements with the size distribution of the NaCl particles being a key parameter.The testing efficiencies of three filter media were tested with three filter velocities with 5 NaCl size distributions to analyze the relationship between the NaCl size distribution and the testing efficiency.Experimental results show that the filtration efficiency is more strongly related to the NaCl particles size distribution than filter media.For NaCl particles having a count median diameter(CMD) of(0.09±0.02) μm and a geometric standard deviation(GSD) of less than 1.78,the efficiency differences due to the size variation will not affect the filter media evaluations.
What problem does this paper attempt to address?