Impact of Integrated Grounding Wire on Traction Return Current in Direct Power Supply System

董安平,张雪原,邓明丽,陈纪刚,吴广宁
DOI: https://doi.org/10.3969/j.issn.0258-2724.2010.01.015
2010-01-01
Journal of Southwest Jiaotong University
Abstract:In order to investigate the distribution of traction return current for high-speed and heavy-load railways,the equivalent impedances of rail and integrated grounding wire were calculated by analyzing their electrical circuits.With the equivalent impedances,the ratio of traction currents in the rail and integrated grounding wire was obtained.A calculational result based on the typical parameters of ballastless track of Shuining-Chongqing railway indicates that the maximum current flowing through the integrated grounding wire is 19.7% of the traction return current,and it is consistent with the testing result.
What problem does this paper attempt to address?