The Clinic Application of 18F-FDG Coincidence Imaging in Detecting Tumors and Metastases
李林法,朱阳军,沈文华,赵葵,闻世凤,罗旭光,程维荷
DOI: https://doi.org/10.3321/j.issn:0253-3219.2003.11.016
2003-01-01
Nuclear Techniques
Abstract:To evaluate the clinical usefulness of 18F-FDG coincidence imaging in detecting tumors and metastases, 87 patients with suspected malignant or recurrent tumors were studied. 259-298MBq I8F-FDG was injected, then 40 -60 min after injection the patients underwent I8F-FDG coincidence imaging using GE HAWKEYE Coincidence SPECT in supine position. After reconstruction using iterative algorithm,we obtained the transaxial,coronal and sagittal sections with X-ray attenuation correction. The images were interpreted visually, and also analyzed with operative, histological, CT/MRI and follow-up studies. There were 61 positives, including 5 false-positives and 56 true-positives; 26 negatives, including 2 false-negatives and 24 true-negatives in altogether 87 patients. 136 lesions were detected by 18F-FDG coincidence imaging,including 41 lymph node and remote metastases. In all patients with suspected malignant tumors, the sensitivity, specificity, positive predictive values, negative predictive values and accuracy of 18FHFDG coincidence imaging were 96.6% (56/58), 82.8% (24/29), 91.8% (56/61), 92.8% (24/26) and 92.0% (80/87) respectively. 18F-FDG coincidence imaging had high sensitivity and specificity in tumor diagnosis, and had unique advantages in ascertaining tumor's nature and in detecting recurrence or metastases, and it was also a valuable diagnostic and investigative method for patients with cancer.
What problem does this paper attempt to address?